Issue 36

A. Namdar et alii, Frattura ed Integrità Strutturale, 36 (2016) 168-181; DOI: 10.3221/IGF-ESIS.36.17 177 Model without crack, NSC Model without crack, UHPC Model 1, NSC Model 1, UHPC Model 2, NSC Model 2, UHPC Figure 11 : Von Mises of different models with applied forcing frequency. NSC UHPC Crack length (mm) Von Mises (MPa) Crack length (mm) von Mises (MPa) 0 5.460 0 5.766 75 5.262 75 5.550 150 5.280 150 5.542 Table 8 : Maximum von Mises Vs crack length with applied forcing frequency.