D. Cerniglia et alii, Frattura ed Integrità Strutturale, 22 (2012) 56-68 ; DOI: 10.3221/IGF-ESIS.22.07 56 Contact between the components of a knee prosthesis: numerical and experimental study Contatto tra i componenti di una protesi di ginocchio: studio numerico e sperimentale D. Cerniglia, T. Ingrassia, L. D’Acquisto, M. Saporito Dipartimento di Ingegneria Chimica, Gestionale, Informatica, Meccanica Università degli Studi di Palermo - viale delle Scienze, 90128 Palermo (Italy) donatella.cerniglia@unipa.it D. Tumino Facoltà di Ingegneria, Architettura e delle Scienze Motorie Università degli Studi di Enna Kore - Cittadella Universitaria, 94100 Enna (Italy) A BSTRACT . The aim of this work is the analysis of the contact area in a knee prosthesis using two different approaches. In particular, the interface between the femoral component and the polyethylene insert has been studied both numerically and experimentally. The interest in studying the contact area is related to the fact that the wear of the polyethylene insert, due to the high contact pressures, represents one of the major causes of failure of the total knee prosthesis. The possibility to evaluate the contact area at different loads and mutual position between femur and tibia is, therefore, of fundamental importance to study the service life of a prosthesis and to improve its performance. The finite element numerical approach has required the acquisition, through reverse engineering, and CAD modelling of the prosthetic components. Then the FEM simulations have been developed considering two different load conditions. In order to compare the calculated data, the same load configurations have been used for experimental tests based on ultrasonic method. In this case, some preliminary tests were required to calibrate the system depending on the particular characteristics of materials, geometries and surface finish of the prosthesis. The results show a good correlation between the data obtained with the two different approaches and, consequently, a good level of reliability of the procedures developed for the numerical and experimental evaluation of the contact area. The numerical procedure can be used to determine the area for different angles and loads, but especially in the design phase. The ultrasonic technique can be used to validate the numerical data. S OMMARIO . Scopo del presente lavoro è lo studio dell’area di contatto in una protesi di ginocchio utilizzando due differenti approcci. In particolare è stata studiata l’interfaccia fra la componente femorale e l’inserto in polietilene sia numericamente che sperimentalmente. L’interesse allo studio dell’area di contatto è legato al fatto che, molto spesso, l’usura dell’inserto in polietilene, dovuta alle elevate pressioni di contatto, rappresenta una delle principali cause di fallimento delle protesi totali di ginocchio. La possibilità di valutare l’area di contatto al variare dei carichi e della posizione reciproca fra femore e tibia è, quindi, di fondamentale importanza per lo studio della vita utile di una protesi e per cercare di migliorarne le prestazioni. L’approccio numerico agli

RkJQdWJsaXNoZXIy MjM0NDE=