Issue 20

A. Borruto et alii, Frattura ed Integrità Strutturale, 20 (2012) 22-31; DOI: 10.3221/IGF-ESIS.20.03 23 An analysis of Cr-Mo steels pipes corrosion is carried out in this paper. The internal surface of pipes has been exposed to a corrosive environment and the effect will be showed. E XPERIMENTAL he corrosion of pipes in a furnace used to preheat crude oil in an atmospheric distillation plant was considered. The observed pipes are made of Cr-Mo steel, as it will be shown later by EDS analysis. The dimensions of the as- received pipes are as follows: external diameter 115 mm, thickness 4,3 mm. Before investigation, the pipes were exposed to in service conditions for about four years. Over the first two years, the pipes worked with a constant composition and flow rate crude oil-fed: a) charge: 480 ton/h of crude (48% Arabian Light crude and 52% Arabian Medium crude); b) feed charge states in the furnace: at entrance, liquid; at exit, partly vapour; c) the furnace temperatures: at entrance, 340°C; at exit, 400°C; d) average speed of fluid in the pipes in the furnace: 2.1 m/s; e) sulphur percentage S% = 2.12; f) TAN of the feed charge entering the furnace 0.1. During year 3 the charge of the crude oil was modified. The Fig. 1 shows the trend of the charge v.s. the time (month) and highlights the following differences in crude composition: 1) Arabian Light: a maximum equal to 95% in the feed takes place in April month. This value remains steady AT 60% in the following month. 2) Arabian Medium: its percentage in the feed falls to 0% in April, along with the increase in Arabian Light’s percentage. The flow rate of Arabian Medium increases in May and reaches about 21% in the following months. 3) Ural: low percentages (about 13%) have been present since January. Maximum value of 37% takes place in May, and then stabilizes at 11%. 4) Since May small amounts (about 2%) of Buri, Kirkuk, Iranian Heavy and Bonny Light were added. The crude composition in December was: 61.93% Arabian Light, 14.16% Arabian Medium, 23.91% of different feeds (4.9% Ural, 11.05% Kirkuk, 5.93% Buri and 2.03% Bonny Light). This data are processed in the atmospheric distillation unit. The flow rate composition (weight%) of the crude oil blend feeding the atmospheric distillation unit was measured in the last three day of every month. Given that the three readings did not differ much, the average value has been used as representative information for each month. To make the graph easier to read and understand, the markers have been connected to each other. Figure 1 : Crude composition (weight %) during the penultimate operating year. During the last operating year another variation in the charge of the crude oil was observed. Fig. 2 shows the trend of the charge v.s. time and highlights the following differences on crude composition: T

RkJQdWJsaXNoZXIy MjM0NDE=