High-rate J-Testing of toughened nylon 6/6: application of the load separation criterion
Last modified: 2008-06-04
Abstract
JR curve of toughened nylon 6/6 at high loading rates is determined by means of the load separation criterion. The results are compared with those measured using the multi-specimen testing procedures proposed by ESIS Technical Committee 4 (Polymers, Adhesives and Composites).