Digital Repository, ECF15, Stockolm 2004

Font Size: 
Steady-state measurement of the interface fracture resistance in wafer bonding
Y. Bertholet, F. Iker, X. X. Zhang, J .P. Raskin, T. Pardoen

Last modified: 2013-02-08

Abstract


A steady-state wedge-opening test has been developed in order to measure the work ofseparation of bonded silicon wafers. Non-steady-state and steady-state measurements arecompared. Significant influence of i) the surface treatment, ii) the annealing time andtemperature and iii) the crack velocity on the toughness is observed and related to theinterface chemistry. A methodology based on the insertion of a thin plastically deforminglayer near the interface is proposed in order to extract the critical strength of the interface aswell as to increase the fracture toughness.

Full Text: PDF