Font Size:
Steady-state measurement of the interface fracture resistance in wafer bonding
Last modified: 2013-02-08
Abstract
A steady-state wedge-opening test has been developed in order to measure the work ofseparation of bonded silicon wafers. Non-steady-state and steady-state measurements arecompared. Significant influence of i) the surface treatment, ii) the annealing time andtemperature and iii) the crack velocity on the toughness is observed and related to theinterface chemistry. A methodology based on the insertion of a thin plastically deforminglayer near the interface is proposed in order to extract the critical strength of the interface aswell as to increase the fracture toughness.
Full Text:
PDF